Moisture Measuring Sensors
FSH - The unrivaled

FSH - The unrivaled

High temperatur sensor for up to 190°C measuring medium temperature; ambient temperature max 80°C, abrasion cober ceramic or teflon, degree of protection IP68

Product description

Werne & Thiel moisture measuring sensors always represent the latest technology of our well-proven high frequency measuring method and offer unique precision and reliability. Since decades we are in touch with our customers to be able to always give him an innovative product perfectly fitting his needs.

FSH Sensors of the newest generation are available by different replaceable wear protections:
• Special-Ceramic (extremely abrasion resistant)
• Teflon (for sticky materials)

Easy calibration of the sensor by integrated adjustment unit.
Output Signal: 0-10 V or 0/4-20mA - no additional processing unit required
Operating voltage: 9-30V DC
Specific appointment of moisture thanks internal digital linearization of the measuring
signal
Samples of application area:
• Moisture content of many high temperature materials (up to 190°C)
• Reprocessing of foundry sand
• Moisture content of quartz sand e.g. for glass manufacture
• Quality optimizing in food processing
• Biological waste
• Ceramic powders and pastes; metal oxides
• Sludge from the sewage plants
• and many more

Technical data

Signal output Standard: 0-10 V
Output load resistance: 100 kohm

Option: 0-20 mA or 4-20 mA
Load resistance: 500 Ohm 0.1%, TK = 25 ppm
Protection against Overvoltage, reverse polarity and short-circuit of the output.
All inputs and outputs are protected against disturbances with suppression
filters.
Umgebungsbedingungen Betriebssicher: +0,5°C bis +190 °C an der Messfläche,
zulässige Umgebungstemperatur max. 80 °C
Lagerung: -25 °C bis +65 °C
Depth of insertion of the sensor edge continuously adjustable from 0 mm to app. 50 mm
Abrasion Protection of Sensor Ceramic: 3 mm thick, extremely good resistance to abrasion (changeable)
Teflon: for sticky materials and for use in the food industry (changeable)
Probe supply +9 VDC up to +30V DC
Current input 165 mA for 10 V supply
125 mA for 15 V supply
70 mA for 24 V supply
58 mA for 30 V supply
Material-Temperature sensor PT100 (optional)
Connection to the probe Plug-/ screwable connecting cable 5 x 0.22 mm2 shielded
all types of probes Cable is assembled with metallic terminal sleeves.
cable lenght 4 meter
Maximum Signal Values Voltage output: -0,7 V to app. 12V (RL = 100 k Ohm)
Current output 0-20 mA: -1.4 mA to app. 24 mA (Load = 500 Ohm)
Current output 4-20 mA: +4 mA to app. 24mA (Load = 500 Ohm)
Measurement range and internal calibration of probe 0 and % adjusting trimmer for calibrating the probe
These allow one to adjust the measuring window of the probe to the desired range of moisture measurements for the material.
Accessible only through a water tight screw on the probe back.
Option: external box with 0-and% adjustment unit.
Protection level for the probes IP68
Conformance Conforms to CE standard EMV89/336EWG

Technical documentations

Equipment Description Moisture measuring probes Type FS(x)

Equipment Description Moisture measuring probes Type FS(x)

germanenglish

Brochures

Online moisture measureung in biomasses

Online moisture measureung in biomasses

german

Online moisture measureung in concrete production

Online moisture measureung in concrete production

german

Online moisture measureung in grain

Online moisture measureung in grain

german

FSH - Flyer

FSH - Flyer

english


Privacy policyAbout us
© 2024 Werne & Thiel GmbH
 
stop autoplay vorheriges Bild nächstes Bild Galerie schließen